Batscan − Technical Specifications


General System Overall
Bus Network Value Unit NoteCondition
Max cable segments (Sub Networks) 240 bus/star topology
Max hierarchical levels 4
Max total number of nodes 2404 1, 2
Signaling interface RS485
Communication protocol Proprietary
Min transmission rate 115200b/s
Max transmission rate 2 Mb/s
 
Bus Network Segment Value Unit NoteCondition
Max cable length
vs cable type
1000 m Belden 3082A
500 Belden 3084A
200 Modular-6 (RJ12)
100 Modular-4 (RJ11)
Max distributed Power 15 W
Max distributed Voltage 16 V
Max distributed Current 1.5 A
Max number of nodes 240 2
Notes:1. addressable units, practically limited to distributed power suppy.
2. nodes = Data Acquisition Modules or Sub-Networks.


Computer Interface & Data Acquisition Modules
All modules Value Unit NoteCondition
Isolation voltage ±4 kV
±6 -HV version
Measured temperature resolution 0.5 °C
Operating temperature range +10 − +40 °C
Time resolution 10 µs 1
Power supply voltage range 6 to 16 V
 
Block Voltage Modules BA673 Value Unit NoteCondition
Measured block/cell voltage channels 8 in series
Probe resistance 2 2
Differential input impedance 6 3
Max measuring current ±20 µA 8 x 15 V
Measuring voltage range ±20 V
Measuring accuracy ±0.1 % 4
Measured voltage resolution 1 mV
Continuous common mode voltage ±500 V
±800 -HV version
Continuous over-voltage ±3 kV
Peak over-voltage ±10 kV 10µs pulse
Power supply current 2 mA
 
String Current Modules BA672-CT Value Unit NoteCondition
Measured string current channels 4
Input impedance 1
Measuring voltage range ±12 V 5
Measuring accuracy ±0.1 % 4, 6
Power supply current 30 mA + 50mA/CT
Notes:1. Using 240 x over-sampling.
2. The probe resistor is integrated in terminal connector.
3. Including probe resistance.
4. After calibration.
5. Output voltage from current transducer is ± 5V at nominal (FS) current.
6. Not including error from current transducer (typical 1%FS).